城市轨道交通全自动运行线路车站空调 系统风水联动调试分析
谭玉良
Analysis of Station Airconditioning System Wind-water Joint Commissioning of Urban Rail Transit FAO Lines
TAN Yuliang
-
作者信息:上海申通轨道交通研究咨询有限公司, 200070, 上海
-
Affiliation:Shanghai Shentong Rail Transit Research & Consultancy Co., Ltd., 200070, Shanghai, China
-
关键词:
-
Key words:
-
DOI:10.16037/j.1007-869x.2023.02.026
-
中图分类号/CLCN:U231.5
-
栏目/Col:应用技术
摘要:
以上海某轨道交通FAO(全自动运行)线路车站风水联动调试为案例,对其调试思路进行了探索,梳理出调试过程中的相关设备。将风水联动调试划分为4个主要阶段,深入总结每个阶段调试过程中的问题并提出解决方案。对建设管理方、设计单位、运营方、集成商提出了风水联动调试的合理化建议。
Abstracts:
Taking the wind-water joint commissioning of a FAO (fully automatic operation) rail transit line station in Shanghai as study case, the commissioning ideas are explored and the relevant equipment in the commissioning process are sorted. The wind-water joint commissioning is divided into four main stages, and the problems in the commissioning process of each stage are summarized in depth and solutions are proposed. Reasonable suggestions are put forward to construction management, design unit, operator and integrator about the wind-water joint commissioning.
- 上一篇: 高铁物流运输模式及其可行性