Abstract:
Taking Ningbo-Fenghua intercity railway project as example, a 3D analysis model is established by Midas Civil software. Analysis is carried out on the aseismic performance of station structure under common and rare seismic actions according to the relevant provisions in the Code for Seismic Design of Urban Rail Transit Structures, providing referrable full analysis process for research on aseismic performance of the horizontal double-column elevated station based on rail transit related specifications.