南京地铁地面信号设备故障分析
戴荣武
Analysis of Ground Signal Equipment Failure in Nanjing Metro
DAI Rongwu
-
作者信息:南京地铁运营有限责任公司通号分公司,210012,南京
-
Affiliation:Signal & Communication Branch, Nanjing Metro Operation Co., Ltd., 210012, Nanjing, China
-
关键词:
-
Key words:
-
DOI:10.16037/j.1007-869x.2019.12.031
-
中图分类号/CLCN:U231.7
-
栏目/Col:应用技术
摘要:
介绍了南京地铁1号线及南延线地面信号设备故障,对该故障存在的风险、隐患及原因进行了分析。在此基础上研发了信号机双熔丝转换装置,并将该装置成功应用于南京地铁1号线。
Abstracts:
The ground signal equipment failure on Nanjing metro Line 1 and the south extension line are introduced, the existing risks, hidden dangers and causes of the equipment failure are analyzed. On this basis, the double fuse conversion device of signal controller is developed and applied on Nanjing metro Line 1 successfully.
- 上一篇: 城市轨道交通运营仿真实训系统的建设
- 下一篇: 城市轨道交通信号系统的实时数据接口研究