超级电容储能式有轨电车充电装置输出过电压分析及保护
邱亮王晓陶正华
Analysis and Protection of Output Over-voltage for Energy Storage Tram Charging Device
QIU LiangWANG XiaoTAO Zhenghua
-
作者信息:南瑞集团(国网电力科学研究院)有限公司, 211106, 南京
-
Affiliation:NARI Group(State Grid Electric Power Research Institute) Co., Ltd., 211106, Nanjing, China
-
关键词:
-
Key words:
-
DOI:10.16037/j.1007-869x.2020.01.017
-
中图分类号/CLCN:TM862;U482.1
-
栏目/Col:研究报告
摘要:
海南三亚有轨电车示范线的有轨电车充电装置在恒压充电过程中频繁发生输出过电压故障。对输出电压进行实测,并对过电压原因展开分析。分析发现:在充电装置充电末期,一旦超级电容端电压超过821 V并持续10 s,就会触发故障保护,高速断路器保护断开。通过分析定位过电压产生原因,最后提出解决建议。
Abstracts:
Since the over-voltage failure frequently occurred in constant voltage charging process of the charging device, which is installed in trams on Sanya Demonstration Line in Hainan Province, the output voltage is measured and the causes of over-voltage are analyzed. According to the analysis, at the charging end of the device, when the super capacitor terminal voltage is over 821 V for 10 s, the fault protection will be triggered and the high-speed breaker protection be disconnected. After detection of the over-voltage causes, solutions are proposed accordingly.
引文 / Ref:
邱亮,王晓,陶正华.地铁车辆轮对异常磨耗原因及控制措施[J].城市轨道交通研究,2020,23(1):72.
QIU Liang,WANG Xiao,TAO Zhenghua.Analysis and Protection of Output Over-voltage for Energy Storage Tram Charging Device[J].Urban mass transit,2020,23(1):72.
QIU Liang,WANG Xiao,TAO Zhenghua.Analysis and Protection of Output Over-voltage for Energy Storage Tram Charging Device[J].Urban mass transit,2020,23(1):72.
- 上一篇: 高铁物流运输模式及其可行性
- 下一篇: 新冠肺炎疫情防控与新型城市轨道交通系统开发